Class CC and 10x38 mm Fuse Holders 811 Series - WAGO Corporation
Class CC and 10x38 mm Fuse Holders 811 Series - WAGO Corporation
Complete with CAGE CLAMP® technology, the 811 fuse holder maintains WAGO's legacy of reliability and ease of use. These Class CC and Midget style fuse holders provide maintenance-free, vibration-proof, and corrosion-resistant connections. Lever actuation makes for a user-friendly experience, further simplifying ...

Altech Corp - CB1038-1/I - 10X38 1 POLE FUSE HOLDER W/NEON ...
Overview. Fuse bases secure fuses in place and ensure proper electrical connections. They are available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole designs, with optional LED or neon indicator. Features: DIN-rail mount. Types 10x38 are UL Recognized. CC Types are UL Listed. Plastic parts are made of material resistant to ...

Modular Fuse Holders - Altech Corp.
Modular Fuse Holders - Altech Corp.
10x38 Midget Fuse Holders. Pole. Without. With LED. Fuse. Max Voltage & Current. Drawing. Configuration. Indication. Indication. Size. IEC. UL. No. PCF 10 & PCF 10 LED. 1-pole. 002550001. 002550011. 10x38. 690V AC / 32A. 600V AC/DC / 30A. 1. 1-pole+N. 002550002. 002550012. 10x38. 690V AC / 32A. 600V AC/DC ...

Fuse Holders and Blocks - Cooper Bussmann
Fuse Holders and Blocks. Global Modular Fuse Holders. CH Series - 8x32, 10x38, 14x51, 22x58, Class CC. Specifications. Description: The 'CH' line of modular fuse holders accommodates many fuses from around the world, including North American Class-CC, Midget,. Class gR, aR HSF, and IEC Industrial Ferrule (Class ...

Cylindrical Fuse Links and Cylindrical Fuse Holders - Industry Mall ...
Cylindrical Fuse Links and Cylindrical Fuse Holders - Industry Mall ...
Cylindrical Fuse Links and Cylindrical Fuse Holders; Fuse Holders in Size 10 x 38 mm and Class CC. UL Fuse Systems; Busbar Systems; 3NA, 3ND LV HRC Fuse Systems; SITOR Semiconductor Fuses; Photovoltaic Fuses. Overvoltage protection devices. SENTRON Communication-Capable Circuit Breakers; Switching ...

DF101 - TeSyS fuse-disconnector - 1P - 25A - fuse size 10 x 38 mm ...
Can the GV2 cabling accessories, such as GV2G245, GV2G345, GV2G445, GV2G05 be used with the LS1D30 fuse holders? Product Line: Tesys GV Manual Starter and Protectors. Where is the coil voltage or coil voltage code located on the LC1D09-D32 contactors? Where is the coil voltage or coil voltage code located on ...

FS-033 600V 32A 3 Pole 10x38 Cartridge Fuse Holder - Shining E&E ...
FS-033 600V 32A 3 Pole 10x38 Cartridge Fuse Holder - Shining E&E ...
FS-033 600V 32A 3 Pole 10x38 Cartridge Fuse Holder Rated Voltage: 600V Rated Current: 32A Dimension: 72.0 x 52.5 x 56.0 mm (L x W x H) Install Type: 35mm Din Rail Mounted (TA-001A / TA-001S) Certificate: DC / AC is available. Without LED Lamp. Suitable for 10x38mm Ceramic Tube Fuse. Characteristic: RoHS ...

Fuse carrier - for industrial cylind cartridge fuse 10 x 38 mm - 500 V~ - 1P
For industrial cylindrical cartridge fuses type aM or gG. Conform to standard IEC 60269-2; Isolators conform to IEC 60947-3; Icc: 20 kA with 8.5 x 31.5 cartridge fuse; 100 kA with 10 x 38 cartridge fuse. Fuse not supplied. Single pole. Cartridge dimensions : 10 x 38 mm; Voltage : 500 V~; Number of modules : 1.

FUSE
FUSE
In electronics and electrical engineering, a fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby interrupting the current. It is a sacrificial device; once a fuse has operated it is an open circuit, and it must be replaced or rewired, depending on type.
Fuses have been used as essential safety devices from the early days of electrical engineering. Today there are thousands of different fuse designs which have specific current and voltage ratings, breaking capacity and response times, depending on the application. The time and current operating characteristics of fuses are chosen to provide adequate protection without needless interruption. Wiring regulations usually define a maximum fuse current rating for particular circuits. Short circuits, overloading, mismatched loads, or device failure are the prime reasons for fuse operation.

Thermal fuse
Thermal fuse
Thermal fuse is a cutoff which uses a one-time fusible link. Unlike a thermal switch which may automatically reset itself when the temperature drops, the thermal fuse is more like an electrical fuse: a single-use device that cannot be reset and must be replaced when it fails or is triggered. A thermal fuse is used when the overheating is a result of a rare occurrence, such as failure requiring repair (which would also replace the fuse) or replacement at the end of service life.
One mechanism is a small meltable pellet that holds down a spring. When the pellet melts, the spring is released, separating the contacts and breaking the circuit. The Tamura LE series, NEC Sefuse SF series, Microtemp G4A series, and Hosho Elmwood D series, for example, may use alloy pellets that contain copper, beryllium, and silver to melt at a precise temperature. is a cutoff which uses a one-time fusible link. Unlike a thermal switch which may automatically reset itself when the temperature drops, the thermal fuse is more like an electrical fuse: a single-use device that cannot be reset and must be replaced when it fails or is triggered. A thermal fuse is used when the overheating is a result of a rare occurrence, such as failure requiring repair (which would also replace the fuse) or replacement at the end of service life.
One mechanism is a small meltable pellet that holds down a spring. When the pellet melts, the spring is released, separating the contacts and breaking the circuit. The Tamura LE series, NEC Sefuse SF series, Microtemp G4A series, and Hosho Elmwood D series, for example, may use alloy pellets that contain copper, beryllium, and silver to melt at a precise temperature.

Resettable fuse
Resettable fuse
polymeric PTC device is made up of a non-conductive crystalline organic polymer matrix that is loaded with carbon black particles
[2] to make it conductive. While cool, the polymer is in a crystalline state, with the carbon forced into the regions between crystals, forming many conductive chains. Since it is conductive (the "initial resistance"),
[3] it will pass a current. If too much current is passed through the device the device will begin to heat. As the device heats, the polymer will expand, changing from a crystalline into an amorphous state.
[4] The expansion separates the carbon particles and breaks the conductive pathways, causing the device to heat faster and expand more, further raising the resistance.
[5] This increase in resistance substantially reduces the current in the circuit. A small (leakage) current still flows through the device and is sufficient to maintain the temperature at a level which will keep it in the high resistance state.  Leakage current can range from less than a hundred mA at rated voltage up to a few hundred mA at lower voltages. The device can be said to have latching functionality.[
6] The hold current is the maximum current at which the device is guaranteed not to trip. The trip current is the current at which the device is guaranteed to trip.
[7]When power is removed, the heating due to the leakage current will stop and the PPTC device will cool. As the device cools, it regains its original crystalline structure and returns to a low resistance state where it can hold the current as specified for the device.
[8] This cooling usually takes a few seconds, though a tripped device will retain a slightly higher resistance for hours, slowly approaching the initial resistance value. The resetting will often not take place even if the fault alone has been removed with the power still flowing as the operating current may be above the holding current of the PPTC. The device may not return to its original resistance value; it will most likely stabilize at a significantly higher resistance (up to 4 times initial value). It could take hours, days, weeks or even years for the device to return to a resistance value similar to its original value, if at all.
[9]A PPTC device has a current rating and a voltage rating.

Fuse Holder
Fuse Holder
Automotive and Commercial Vehicle Fuse Holders. Fuseholders for automotive style fuses including MINI, ATO, MAXI, MIDI, MEGA, JCASE and Universal Glass Fuses. Fuseholders are available for In-Line, Bolt-Down, Panel Mount and PCB applications.

Automotive Fuses
Automotive Fuses
Automotive fuses are a class of fuses used to protect the wiring and electrical equipment for vehicles. They are generally rated for circuits no higher than 32 volts direct current, but some types are rated for 42-volt electrical systems. They are occasionally used in non-automotive electrical products.